"Vaiseshika" High Stability Decade Megohm Box Type : 8400 /8400 HV
Description
High Stability Decade Megohm Box has been designed and fabricated for the first time in India to provide calibration standards for Meggers, Insulation Testers, Insulation Bridges, Megohm Meters, Digital Meters and components comparison. The resistance range is offered from 0.1 Megohm to 1000 Gigaohm (1 Tera) distributed over Seven Decades.
Vaiseshika has two models of this instrument i.e. 8400 & 8400 HV.
Model 8400 is economy model having resistance range 0.1 megaohm to 1000.0 Gigaohm with working voltage upto 1000 Volts DC.
Model 8400 Hv is designed for high voltage working up to 1000 Gigaohm (1 Tera) with working voltage from 1000 Volts to 5000 volts DC.
Features
Good engineering characteristics
Portable in metallic cabinet
Resistance calibration standards
Highly stable & sturdy switches
Built in state of the art system to minimize effect of humidity at high
voltage measurements
Repeatable results
Very high grade ceramic resistors employed
FOR THE FIRST TIME IN INDIA
Vaiseshika is proud of achieving remarkable success in designing & manufacturing High stability Decade Megohm Boxes upto 1000 GigaOhm rated to work on 5000 Volts DC. Vaiseshika is the only Company in India to manufacture such Megohm Boxes.
High stability Decade Megohm Box is Available in two Models:
Type 8400 Economy Model: Voltage range 500 Volts to
1000 Volts DC.
Type 8400-HV (High Voltage): Voltage Range 1000 Volts
to 5000 Volts DC.
Model 8400:
(Economy Model)
Specification
Type
: Portable
Function
; Resistance Calibration Standard
Resistance Range
: 0.1 Megohm to 1000 Giga Ohm (In seven decade dials)
Accuracy
: +/- 2% uptil 1 Giga ohm
: +/- 5% from 1 Giga Ohm to 1000 Gigaohm range
Power rating on 70 C
: 1.5 W
Rated Max. Voltage
: 1000 Volts DC
Stability
: 0.5%
Capability
Decade
Resistance per step
Total Resistance on decade dial
Impressed Voltage
First
0.1
Meg.
1.0
Meg.
1000 Volts DC
Second
1.0 Meg.
10.0
Meg.
1000 Volts DC
Third
10.0 Meg.
100.0
Meg.
1000 Volts DC
Fourth
100.0 Meg.
1000.0
Meg.
1000 Volts DC
Fifth
1.0 Giga
10.0
Giga
1000 Volts DC
Sixth
10.0 Giga
100.0 Giga
1000 Volts DC
Seventh
100.0 Giga
1000.0 Giga
1000 Volts DC
Total Available Resistance : 1111.111 Giga Ohm
Model 8400 HV:
Specification
Type
: Portable
Function
: Resistance Calibration Standard
Resistance Range
: 0.1 Megohm to 1000 Giga Ohm (In seven decade dials)
Accuracy
: +/- 2% uptil 1 Giga ohm
: +/- 5% from 1 Giga Ohm to 1000 Gigaohm range